OVERSEAS STANDARDS & EXPORT READINESS

Overseas Technical Standards & Export Readiness Reference Library

International Standards Mapping, Laboratory Verification Protocols, and Technical Documentation Checklists for Cross-Border Hardware Engineering

Engineering-Grade Standards Alignment & Technical Specification Synergy

Operating as a Hong Kong–Shanghai cross-border industrial synergy and go-global service platform (立足香港、联动沪港的跨境产业协同与出海服务平台) supported by the Shanghai Pudong state-owned ecosystem (依托上海浦东新区国资体系), this library compiles international regulatory standards, laboratory validation parameters, and factory shipment documentation checklists across six core hardware tracks.

Ref IDTechnical Standard TopicPrimary Standards & DirectivesKey Verification MetricsIndustrial Track
UT-STD-01400G/800G & PCIe Gen5 High-Speed Interconnect Compliance (CE/FCC/RoHS/REACH & SI Verification)IEEE 802.3ck · PCIe Gen5 · CE-EMC · FCC Part 15B · RoHS/REACH85Ω ±5% TDR · IL ≤ 0.35 dB · 400× End-FaceDigital Information & High-Density Compute Interconnect (MCIO / SlimSAS / OCuLink / DAC / AEC / Optics)
UT-STD-02OCP Server PSU & Smart Rack PDU Safety Compliance (UL 62368-1 / CE-LVD & Power Harnesses)UL 62368-1 · IEC/EN 62368-1 · CE-LVD · PCIe 5.1 12V-2x6CRPS 80 PLUS Titanium · Zero-U 32A PDU · 16 AWG ThermalHigh-End Equipment & Clean Rack Power (CRPS Redundant PSU / Zero-U Smart PDU / 12V-2x6 Power Whips)
UT-STD-03Industrial Edge AI Computing Physical No-RF & Non-DG Air-Freight Readiness GuideIATA DGR (Non-DG) · CE-EMC · FCC Part 15B · VCCI · NTP/PTPPhysical No-RF BOM · Zero CR2032 (No UN3091) · -20°C to 60°CArtificial Intelligence & Industrial Edge Computing (RK3588 / Jetson Orin Fanless IPCs / Carrier Boards & SOMs)
UT-STD-04Digital Substation & AIDC Power Monitoring IEC 61850 & Grid EMI/EMC Readiness GuideIEC 61850-3 · IEEE 1613 · IEC 61000-6-5 · MMS/GOOSE/SVGOOSE ≤ 3 ms · Level 4 Surge (±4 kV) · PTP < 1 µsGreen Energy & Grid Monitoring Sub-Assemblies (Dry-Type Transformer Sensors / Busway Monitors / PQ Kits)
UT-STD-05AMR Mobile Robotics 3D Vision & Maintenance Sub-Assemblies ISO 3691-4 Safety GuideISO 3691-4 · ISO 13849-1 PLd · IEC 60825-1 · GMSL2/PoEClass 1 ToF/Laser · >5M Drag-Chain Cycles · PLd SafetyEmbodied AI & Industrial Mobile Robotics (3D ToF / Structured-Light Vision / Drag-Chain Harnesses & 4S Spares)
UT-STD-06Medical Power & OEM Sub-Assemblies IEC 60601-1 2×MOPP Isolation & Documentation GuideIEC 60601-1 (Ed. 3.2) · 2×MOPP · IEC 60601-1-2 · ISO 134854000V AC 2×MOPP · Leakage < 100 µA · ISO 13485 CoCLife & Health Medical OEM Sub-Assemblies (2×MOPP Medical PSUs / Endoscope Camera Modules / Diagnostic Harnesses)
UT-STD-0185Ω ±5% TDR · IL ≤ 0.35 dB · 400× End-Face

400G/800G & PCIe Gen5 High-Speed Interconnect Compliance (CE/FCC/RoHS/REACH & SI Verification)

IEEE 802.3ck · PCIe Gen5 · CE-EMC · FCC Part 15B · RoHS/REACH

Covers laboratory signal-integrity (SI) verification and EU/North American electromagnetic compatibility and material compliance for internal MCIO/SlimSAS/OCuLink harnesses, PCIe Gen5 retimers, 400G/800G passive DACs, active electrical cables (AEC), and Layer-1 optical transceivers.

Read Full Technical Standard & Documentation Guide →
UT-STD-03Physical No-RF BOM · Zero CR2032 (No UN3091) · -20°C to 60°C

Industrial Edge AI Computing Physical No-RF & Non-DG Air-Freight Readiness Guide

IATA DGR (Non-DG) · CE-EMC · FCC Part 15B · VCCI · NTP/PTP

Explains factory-level hardware configuration for fanless industrial edge AI computers (RK3588 / Jetson Orin carrier boards): leaving Wi-Fi/BT/cellular pads physically unpopulated (No-RF) and omitting CR2032 lithium metal coin cells in favor of supercapacitor RTC and NTP/PTP synchronization (Non-DG).

Read Full Technical Standard & Documentation Guide →
UT-STD-04GOOSE ≤ 3 ms · Level 4 Surge (±4 kV) · PTP < 1 µs

Digital Substation & AIDC Power Monitoring IEC 61850 & Grid EMI/EMC Readiness Guide

IEC 61850-3 · IEEE 1613 · IEC 61000-6-5 · MMS/GOOSE/SV

Covers protocol conformance and harsh substation electromagnetic immunity (EMI/EMC) requirements for lightweight dry-type transformer thermal/partial-discharge sensors, busway tap-off box monitors, power quality sub-assemblies, and wired No-RF industrial Ethernet switches.

Read Full Technical Standard & Documentation Guide →
UT-STD-05Class 1 ToF/Laser · >5M Drag-Chain Cycles · PLd Safety

AMR Mobile Robotics 3D Vision & Maintenance Sub-Assemblies ISO 3691-4 Safety Guide

ISO 3691-4 · ISO 13849-1 PLd · IEC 60825-1 · GMSL2/PoE

Outlines machinery safety, laser eye-safety, and flex-life qualification standards for Autonomous Mobile Robot (AMR) 3D ToF and structured-light RGB-D vision modules, GMSL2/CoaXPress/GigE high-flex drag-chain harnesses, industrial CAN/RS485 hubs, and 4S wear-part kits.

Read Full Technical Standard & Documentation Guide →
UT-STD-064000V AC 2×MOPP · Leakage < 100 µA · ISO 13485 CoC

Medical Power & OEM Sub-Assemblies IEC 60601-1 2×MOPP Isolation & Documentation Guide

IEC 60601-1 (Ed. 3.2) · 2×MOPP · IEC 60601-1-2 · ISO 13485

Details dielectric isolation (4000V AC 2×MOPP), patient leakage current limits, and ISO 13485 quality documentation for non-finished medical OEM components including 2×MOPP AC/DC power supplies, endoscope imaging sub-modules, and diagnostic interconnect harnesses.

Read Full Technical Standard & Documentation Guide →